Kofax Transformation Modules (KTM) 6.3.1 Fix Pack 7 | Release Date:  July 23, 2020

Problems Resolved in this Fix Pack

1466122 – NLP does not work with Japanese documents. The NLP engine now successfully extracts Japanese named entities successfully.
1460797 – When processing batches through Kofax Transformation Modules the documents are not being classified correctly because they are being locked. Due to a new retry mechanism, documents that are temporarily locked are now successfully processed once that lock is released.

Problems Resolved in previous Fix Packs

1456194 – Auto Folder feature no longer initializing fields on new folders. When used, the Auto Folder feature now initializes fields on new folders as expected.
1444843 – When users attempt to use the Filtering feature within the Open Batch window, the “values” button does not populate with any data for users to select from when a ‘Batch Field’ item is selected. Filtering the Open Batch window now behaves as expected.
1402724 – Validation Fuzzy Database Lookup sorting issue. When using a database that has one or more columns that are not imported in the fuzzy index, the column sorting of of the search results now works as expected.

1441234 – Barcode value is empty once checksum option is enabled. By default, Code39 bar codes that contains asterisks should be recognized with the default FineReader recognition settings. However, if FineReader fails to recognize a Code29 bar code. Using the default settings, you can use scripting to improve the chances of bar code recognition. This is possible because the IsCode39WithOutAsterisk behavior is now available for editing via script. If you want to recognize code 39 bar codes with asterisks when checksum is enabled, you can add the following code to the BeforeLocate event.

Private Sub Document_BeforeLocate(ByVal pXDoc As CASCADELib.CscXDocument, ByVal LocatorName As String)
     If(LocatorName = "BarcodeLocator") Then
         Dim Loc As CscBarcodeLocator
         Set Loc = Project.ClassByIndex(0).Locators.ItemByName(LocatorName).LocatorMethod
         Loc. IsCode39WithOutAsterisk = False
     End If
 End Sub

1404073 – Calling CopyDocument() between MergeDocument() calls causes Out Of Range Exception in SynchronizeXRootFolderToKCBatch. When batch restructuring, the combination of merging and copying documents now performs as expected.
1398810 – Document routing fails in Validation as PDF file is still locked by another process. A PDF can be successfully routed in Validation without causing an error.
1379752 – “Object reference not set to an instance of an object” on opening a batch in Validation – get_IsViewerDocked. This error no longer occurs because the Docking XML is now protected from corruption.
1342366 – Bad performance with Bar Code Locator using FineReader when extracting QR code on color image. By default, QR bar codes should be recognized with the default FineReader recognition settings. However, if FineReader fails to recognize a QR bar code using the default settings, you can use scripting to improve the chances of bar code recognition. This is possible because the AdvancedExtractionMode behavior is now available for editing via script. If you want to recognize QR bar codes, you can add the following code to the BeforeLocate event.

Private Sub Document_BeforeLocate(ByVal pXDoc As CASCADELib.CscXDocument, ByVal LocatorName As String)
     If(LocatorName = "BarcodeLocator") Then
         Dim Loc As CscBarcodeLocator
         Set Loc = Project.ClassByIndex(0).Locators.ItemByName(LocatorName).LocatorMethod
         Loc. AdvancedExtractionMode = False
     End If
 End Sub

1399311 – The Document_Validated is not thrown anymore if Fixpack 16 is installed and reclassify is used. If using Reclassify in AfterFieldConfirmed the Document_Validated event is now successfully raised again when a field is confirmed.
1399142 – TDS Model not working after KTM 6.3 upgrade. Trainable document separation is now successfully classifying and separating documents without issue.
1397124 – If a field is confirmed with holding down the enter key and the next batch is opened automatically then an Object reference error occurs. It is now possible to confirm a field by holding down the Enter key and when the next batch is opened automatically, there is no error.
1375245 – Field Count data missing from “Field Recognition Accuracy Per Day” report. Field Count data is no longer missing from the “Field Recognition Accuracy Per Day” report.
1381523 – Getting error during Validation when trying to confirm a field “… DocumentLoaded: Reclassify is not permitted in the current script function…”. It is now possible to use the Reclassify call in script without this error.
1358251 – Table Evaluation not possible in KTM. Table Evaluation is now performed successfully.
1378131 – Debug DLL Fixes Validation Module “Object Reference” Errors. An error no longer occurs in the Validation Module.
1375723 – Child set reread setting is ignored and parent class setting is used. When a child class has a different locator reread setting than its parent class, the parent reread settings are no longer executed during extraction.
1358297 – Paste grayed out after doing Copy (CTRL+V) once KTM Validation, so you cannot continue doing copy/paste. It is now possible to copy and then paste using the Ctrl-based keyboard shortcuts or the clipboard, as many times as necessary.
1370292, 1352443 – Object reference error is shown when confirming the field that reclassifies the document in script. An error no longer occurs when a document is reclassified in script using the AfterFieldConfirmed event.
1369734 – Datamatrix Barcode is not recognized in KTM anymore. By default, Datamatrix bar codes should be recognized with the default FineReader recognition settings. However, if FineReader fails to recognize a datamatrix bar code using the default settings, you can use scripting to improve the chances of bar code recognition. This is possible because the DetectInvertedZones behavior is now available for editing via script. If you want to recognize Datamatrix bar codes, you can add the following code to the BeforeLocate event.

Private Sub Document_BeforeLocate(ByVal pXDoc As CASCADELib.CscXDocument, ByVal LocatorName As String)
  If(LocatorName = "BarcodeLocator") Then
	  Dim Loc As CscBarcodeLocator
	  Set Loc = Project.ClassByIndex(0).Locators.ItemByName(LocatorName).LocatorMethod
	  Loc.DetectInvertedZones = False
  End If
End Sub

1353640 – PDF file shows rendered without font (squares instead font) in Project Builder and Validation. Squares instead of the built-in PDF font are no longer displayed when rendering a PDF file.
1351693, 1349336 – Delete button grayed out in Validation when selecting multiple images. The Delete button is no longer greyed out in Validation when selecting multiple images.
1343422 – Inherited Advanced Evaluators Cause Crash in Project Builder. Project Builder no longer crashes when a Script Locator is defined before an Advanced Evaluator in the locator hierarchy of an inherited class.
1330287, 1327445 – Document routing fails with PDF document if Batch.CopyDocument is used. It is now possible to successfully route PDF documents.
1329796, 1328209 – Server fails batches: Error in function ProcessBatch: Conversion from string “” to type ‘Integer’ is not valid. An error no longer occurs when an empty or non-existent custom storage string is encountered.
1328691 – Latency with Inbuilt Database script, delay in Validation module. In order to avoid this latency, a project Administrator needs to provide the database connection type to ODBC window in script. A new property called ‘ConnectionType’ is now available.Here are the possible options for this new property.
– EnumConnectionType_Unknown
– EnumConnectionType_Odbc
– EnumConnectionType_OdbcSql
– EnumConnectionType_OdbcOracle
– EnumConnectionType_SqlServer
When you provide the specific ‘ConnectionType,’ this bypasses any additional calls to the database that check the database schema. Sample Script:

With odbDialog
	 .ConnectionType = EnumConnectionType_OdbcSql
	 mSupplier = .ShowDialog (CONNECTION_STRING,TABLE_NAME)
End With


1321559, 1320959 – NLP: All entities have confidence 1. The confidence of an alternative is now the average confidence of all of the located mentions.
1321411, 1320885 – NLP: Locator is throwing error “Zone index out of range”. It is now possible to draw a region on a page and then test or use that region without it causing an error.
1317047, 1317053 – Named Entity Locator does not highlight the best mention. The best mention is now highlighted when viewing the Named Entity Locator results.
1317027, 1317030 – Named Entity Locator loses highlighting when you click TEST again. When testing the Named Entity Locator, all locator alternatives are displayed in the Document Viewer each time the Test button is pressed on the Test Results tab.
1317021, 1317033 – Missing entities in Named Entity Locator. When extraction is performed for the Named Entity Locator, a complete list of entities is now extracted as expected.
1317020, 1317037 – Missing scrollbar in Named Entity Locator. A scrollbar is now displayed when needed.
1315675, 1246992 – There are two processing windows coming for Training Extraction. If there are no documents in a document set, the progress bar window is no longer displayed if Extraction training is performed for that document set.
1313696, 1320629 – Failed to extract entities with an error no language is specified. The Test button on the locator is disabled if no language is configured at the class-level.
1310150, 1305677 – Validation crashing on reclassifying via script. Validation no longer crashes when a user reclassifies via script and then closes the module.
1280195 – Table Locator Extracting Lines Past End of Table Dictionary. The Table Locator now ignores lines extracted after the end of the table is found.
1266814, 1254229 – Name of representation is not changed after overwriting the recognition results. The name of a representation is now updated correctly when OCR is performed on a document that already has extraction results.